Read the below instructions to learn how to implant your cattle with Ralgro® implants. Ralgro® implants are designed for use with the Ralogun™ applicator. Before implanting, ensure the implanting site is clean, disinfected and dry.
(NOTE: The Ralogun™ applicator, which is designed for Ralgro® implants, is NOT compatible with Revalor® implants.)
How to use the Ralogun™ applicator
- Each chamber of the plastic Ralgro® cartridge contains a full dose of Ralgro® implants. Insert the cartridge in the magazine of the Ralogun™ pellet injector with the hole in the axle of the cartridge pointed toward the handle of the Ralogun™ pellet injector. After snapping into place, rotate cartridge clockwise to ensure proper seating, then check window at top to ensure that pellet chamber is aligned with plunger.
- Always use sharp needle. A dull needle tears tissue and makes proper implanting difficult. Be sure that needle is fully seated in Ralogun™ pellet injector. This ensures that pellets will be expelled from the needle as Ralogun™ plunger is extended. Failure to set the needle could cause the last pellet to be left in the needle and not implanted.
- After appropriately restraining the animal to allow access to the ear, cleanse the skin at the implant needle puncture site.
- The implant site is subcutaneous, between the skin and cartilage on the back side of the ear and below the midline of the ear. The implant must not be placed closer to the head than the edge of the auricular cartilage ring farthest from the head. The location for insertion of the needle is a point toward the tip of the ear and at least a needle length away from the intended deposition site. Care should be taken to avoid injuring the major blood vessels or cartilage of the ear. Squeeze trigger of the Ralogun™ pellet injector to deliver a full dose of Ralgro®. Keep trigger depressed while withdrawing the needle to be sure that Ralgro® implants stay in place.
- Wipe needle with cotton or gauze moistened with alcohol or other suitable disinfectant. Do not dip needle in solution because solution clinging to inside of needle will cause plugging of needle.
- Rotate cartridge in direction of arrow until a new dose is visible and centered in window. The Ralogun™ pellet injector is now ready for next implantation.
RALGRO® is a registered trademark of Intervet Inc.; RALOGUN™ is a trademark of Intervet Inc. All trademarks used under license.
Go To United States
Algeria
Argentina
Australia
Austria
Bahrain
Belgium (Dutch)
Brazil
Canada (English)
Chile
Colombia
Croatia
Czech Republic
Denmark
Ecuador
Egypt
Finland
France
Germany
Greece
Hungary
India
Indonesia
Iraq
Ireland
Israel
Italy
Japan
Jordan
Kuwait
Lebanon
Malaysia
Mexico
Morocco
Netherlands
New Zealand
Norway
Oman
Panama
Peru
Philippines
Poland
Portugal
Qatar
Romania
Russian Federation
Saudi Arabia
South Africa
South Korea
Spain
Sweden
Switzerland (French)
Taiwan
Thailand
Tunisia
Turkey
Ukraine
United Arab Emirates
United Kingdom
Uruguay
Yemen
Global
You are now leaving merck-animal-health.ca, a site maintained by Merck Animal Health Canada
The link is provided for your convenience only.
Merck Animal Health makes no warranties or representations of any kind as to the accuracy, completeness, reliability or usefulness of any information contained in third party sites and shall have no liability for any loss or damage of any kind that may arise from your use of such content or information.
Inclusion of any third party link does not imply an endorsement or recommendation by Merck Animal Health.